Pre-Inhibited Propylene Glycol Based Antifreeze Concentrate

Pre-Inhibited Propylene Glycol Based Antifreeze Concentrate is a high-performance heat transfer fluid formulated with propylene glycol (C₃H₈O₂) and a specialized corrosion inhibitor package. It is supplied in concentrated form and must be diluted with deionized water before use, depending on the required freeze protection level.

Key Features

  • ✅ Excellent freeze and burst protection

  • ✅ Advanced corrosion inhibitors for steel, copper, brass & aluminum

  • ✅ Low toxicity compared to ethylene glycol

  • ✅ Suitable for closed-loop systems

  • ✅ Long service life and thermal stability

  • ✅ Non-scaling and system-friendly

KOOL FROST-96(FFG)

Pre-Inhibited Propylene Glycol

Anti-Corrosive/Inhibited Propylene Glycol Based Antifreeze Concentrate

Pre-Inhibited Propylene Glycol is a high-purity heat transfer and antifreeze fluid formulated with advanced corrosion inhibitors to protect metal surfaces in HVAC systems, chillers, refrigeration units, solar heating systems, and industrial cooling applications. Designed to prevent rust, scale formation, and system degradation, this ready-to-use glycol solution enhances thermal efficiency, extends equipment lifespan, and reduces maintenance costs. Suitable for use in closed-loop systems, it offers excellent freeze protection, low toxicity, and long-term stability. Ideal for commercial and industrial applications, Pre-Inhibited Propylene Glycol ensures reliable performance, superior corrosion control, and optimal heat transfer efficiency.

Kool Frost-96 is industrially inhibited Propylene glycol based antifreeze concentrate which utilize a unique corrosion inhibitor package made from non-toxic raw materials. These inhibitors offer superior corrosion protection for most metals including carbon steel, brass, copper, stainless steel, cast iron and many other alloys by creating a passive layer on the surface that contacts the Kool Frost-96 and prevents corrosion. It also stabilizes the pH of the fluid, keeping it in the range that is suitable for the metals in the system. Kool Frost-96 is recommended for use in application where oral toxicity is important or where incidental contact with drinking water is possible. Since the toxicity of heat transfer fluids may be adversely altered in chilling systems, used fluids should be handled with reasonable care.

Causes of Corrosion
Normal Propylene Glycol oxidizes when exposed to air and heat resulting formation of organic acids viz. Glycolic acid, Oxalic acid, Glyoxylic acid and Formic acid etc. These acids then chemically attack and corrode the system metal causing metal loss, pitting and pin hole etc. The corrosion rate of CO2 is a function of partial pressure, temperature, Chloride presence in water and the type of material. There is no corrosion mechanism more damaging on a concentration basis than O2 – small amount of O2, water and chlorides can damage the pipe within a few months.

Application Area

Beverages and Juices
Breweries, Distilleries and Wineries
Dairy and Ice Cream
Packaged Food Freezing
Fish Processing Units
Pharmaceuticals and Bulk Drugs
Edible Oil Industries
Heating and Cooling System
Cold Storage System

Pre-Inhibited Propylene Glycol (PPG) is widely used as a heat transfer and antifreeze fluid in systems where corrosion protection and thermal efficiency are essential. The added corrosion inhibitors help protect metal components such as steel, copper, brass, and aluminum.

1. HVAC Systems

Used in heating, ventilation, and air conditioning systems to provide freeze protection and efficient heat transfer in chilled water and hot water loops.

2. Refrigeration Units

Commonly used in commercial and industrial refrigeration systems to maintain stable low temperatures and prevent pipe freezing.

3. Solar Heating Systems

Acts as a heat transfer fluid in solar thermal panels, protecting the system from freezing and corrosion.

 4. Industrial Cooling Systems

Used in process cooling applications in manufacturing plants, chemical industries, and food processing units to maintain temperature control.

5. Cold Storage Facilities

Provides reliable freeze protection in cold rooms, walk-in freezers, and warehouse cooling systems.

6. Ice Rinks

Used as a secondary refrigerant in ice skating rinks for efficient and uniform cooling.

 7. Data Centers

Helps regulate temperature in liquid cooling systems for servers and IT infrastructure.

8. Food & Beverage Industry

Preferred in applications requiring low-toxicity heat transfer fluids, especially where incidental contact may occur.

Pre-Inhibited Propylene Glycol is valued for its low toxicity, corrosion resistance, freeze protection, thermal stability, and long service life, making it ideal for both commercial and industrial temperature-control applications.

Controlling Corrosion
Corrosion rate in MPY (mills per year) is a standard method of expression but not a good way to express corrosion where pitting is the major failure. Here is some precaution mentioned below:
Maintain high pH
Control gas breakout
Use passive metals
Remove Oxygen
Control velocities
Lower chlorides
Bacteria control
Acid/brine use considerations and alternatives
Liquid removal
Inhibitor injection
coatings

Storage: This product should be stored in original containers in cool and dry place, away from sources of heat, flame and direct sunlight.

Shelf Life: Two year from the date of manufacturing.

Packing: Product is available in 50kg. Jar / 215 kgs. Barrels.

TOP